Find the name of the machine or other HPSS hardware in the list below. The table shows the machine room coordinates the hardware is closest to.

Miscellaneous Hardware
HPSS Production SP
HPSS Test SP
STK Silos, Tape Drives

Miscellaneous

Machine/rackContains
(rack/frame)
Grid Location
(front)
Grid Location
(back)
Description
hpsscw O25 Control workstation (hpssXX)
sal O25 General use
mda-mse O26 Control workstation (mda-X)
val O27 General use
hal S25 General use

HPSS Production SP

Machine/rackContains
(rack/frame)
Grid Location
(front)
Grid Location
(back)
Description
HPSS SP Frame #1 V25W28SP Frame #1
 hpss01V25W28HPSS Metadata, Servers
 hpss03V25W28HPSS Sammi, SSA Disk/Tape Mover,
pftp, hsi
 hpss05V25W28HPSS SSA Disk/Tape Mover,
pftp, hsi
 hpss07V25W28HPSS SSA Disk/Tape Mover,
pftp, hsi
 hpss09V25W28HPSS SSA Disk/Tape Mover,
pftp, hsi
 hpss11V25W28HPSS SSA Disk/Tape Mover,
pftp, hsi
 hpss11V25W28HPSS SSA Disk/Tape Mover,
pftp, hsi
 hpss15V25W28HPSS SSA Disk/Tape Mover,
pftp, hsi
HPSS SP Frame #2 X25Y28SP Frame #2
 hpss17X25Y28MDAS use
 hpss18X25Y28MDAS use
 hpss19X25Y28MDAS use
 hpss20X25Y28MDAS use
 hpss21X25Y28General use
 hpss22X25Y28General use
 hpss23X25Y28General use
 hpss24X25Y28HPSS SSA Disk/Tape Mover
(tiny cos)
HPSS SP Frame #3 Y25Z28SP Frame #3
 hpss33Y25Z28HPSS Accounting
 hpss34Y25Z28General use
 hpss35Y25Z28HiPPi/FC test
 hpss36Y25Z28HiPPi/FC test
 hpss37Y25Z28HPSS Tape Mover
 hpss38Y25Z28HPSS Tape Mover
 hpss39Y25Z28HPSS Tape Mover
 hpss40Y25Z28HPSS Tape Mover
 hpss41Y25Z28HPSS Tape Mover
 hpss43Y25Z28HPSS Tape Mover
 hpss45Y25Z28HPSS FC Disk/Tape Mover
 hpss47Y25Z28HPSS FC Disk/Tape Mover

HPSS Test SP

Machine/rackContains
(rack/frame)
Grid Location
(front)
Grid Location
(back)
Description
TEST SP Frame #1 AA25BB28TEST SP Frame #1
 mda-1AA25BB28HPSS TEST
 mda-3AA25BB28HPSS TEST
 mda-5AA25BB28HPSS TEST
 mda-7AA25BB28HPSS TEST

STK Silos, Tape Drives

Machine/rackContains
(rack/frame)
Grid Location
(front)
Grid Location
(back)
Description
4490#1 X23 3490 Tape drives w/autoloader
4490#2 W23 3490 Tape drives w/autoloader
4791 V23 4490 Drive controller
9330 LMU S22 Library Management Unit
LSM 0,0 R6 9310 LSM #0
LCU 0,0 R6 9311 LCU #0
CAP 0,0,0 R6 CAP #0
C12 Frame 0,0,7 V2 C12/14 Frame (drives 0,0,7,0-3)
 3590 0,0,7,0V2 Drive 0,0,7,0
 3590 0,0,7,1V2 Drive 0,0,7,1
 3590 0,0,7,2V2 Drive 0,0,7,2
 3590 0,0,7,3V2 Drive 0,0,7,3
STK Frame 0,0,10 Q4 STK Frame (drives 0,0,10,0-9)
 3590 0,0,10,0Q4 Drive 0,0,10,0
 3590 0,0,10,1Q4 Drive 0,0,10,1
 3590 0,0,10,2Q4 Drive 0,0,10,2
 3590 0,0,10,3Q4 Drive 0,0,10,3
 3590 0,0,10,4Q4 Drive 0,0,10,4
 3590 0,0,10,5Q4 Drive 0,0,10,5
 3590 0,0,10,6Q4 Drive 0,0,10,6
 3590 0,0,10,7Q4 Drive 0,0,10,7
LSM 0,1 CC5 9310 LSM #1
LCU 0,1 CC5 9311 LCU #1
CAP 0,1,0 CC5 CAP #1
C12 Frame 0,1,9 BB9 C12/14 Frame (drives 0,1,9,0-3)
 3590 0,1,9,0BB9 Drive 0,1,9,0
 3590 0,1,9,1BB9 Drive 0,1,9,1
 3590 0,1,9,2BB9 Drive 0,1,9,2
 3590 0,1,9,3BB9 Drive 0,1,9,3
C12 Frame 0,1,10 DD8 C12/14 Frame (drives 0,1,10,0-3)
 3590 0,1,10,0DD8 Drive 0,1,10,0
 3590 0,1,10,1DD8 Drive 0,1,10,1
 3590 0,1,10,2DD8 Drive 0,1,10,2
 3590 0,1,10,3DD8 Drive 0,1,10,3
LSM 0,2 Z10 9310 LSM #2
LCU 0,2 Z10 9311 LCU #2
CAP 0,2,0 Z10 CAP #2
C12 Frame 0,2,9 Y14 C12/14 Frame (drives 0,2,9,0-3)
 3590 0,2,9,0Y14 Drive 0,2,9,0
 3590 0,2,9,1Y14 Drive 0,2,9,1
 3590 0,2,9,2Y14 Drive 0,2,9,2
 3590 0,2,9,3Y14 Drive 0,2,9,3
C12 Frame 0,2,10 AA12 C12/14 Frame (drives 0,2,10,0-3)
 3590 0,2,10,0AA12 Drive 0,2,10,0
 3590 0,2,10,1AA12 Drive 0,2,10,1
 3590 0,2,10,2AA12 Drive 0,2,10,2
 3590 0,2,10,3AA12 Drive 0,2,10,3
X XXDD